PAL16R6 with VP 890 Reply  
handsome
Maverick74
Hi,

I need to substitute an AMD PAL16R6 -20pin

The VP 890 is ok for it? or do I need to buy an another programmer?

..or an adapter?

Let me know

Thanks
Marco

Last post : Re:PAL16R6 with VP 890 Reply: lxl
sorry,it is elder chip. no

All replies (3) [ Posted:2015-02-25 03:50:56 ] Edit Administer TOP"

vp-996 Reply  
handsome
airton.bento
Hi!

I have a VP-996 programmer and I am trying record an AT89S2051 soic, if I use an adapter with paralel mode it works, but if I try with adapter ISP with the cable It works ( read, prog config, compare) but doesn&#180;t erase and doesn&#180;t program, when I interchange MOSI per MISO, Erase It works, only program doesn&#180;t works, I upgrade my version today 4.6.5,the message it&#180;s:


Last post : Re:vp-996 Reply: gxj
sorry,the isp fuse can change only in paralel mode .

All replies (9) [ Posted:2015-02-07 02:34:53 ] Edit Administer TOP"

H27U1G8F2BTR BC Reply  
handsome
lelobq
Hello , I made two dump a H27U1G8F2BTR BC memory but when I record on another device the equipment does not work , this dump may have errors ? I made comparisons and were identical but as I mentioned recording on another device does not work ( the unit) is certainly making dump with errors. I use VP990 , please need urgent help
Last post : Re:H27U1G8F2BTR BC Reply: myx1
1.program mode:button "config",choose "hard copy(verify)" and "used(page=2112)".then read one and program the other.
auto prg choose "earse"and "program" on the right side.
2.if fail,you may choose "hard copy(no verify)" then have a try.
3.if it is still not working,maybe the bad blocks area are used for value datas,this you have to use another one.
All replies (1) [ Posted:2015-02-20 07:00:52 ] Edit Administer TOP"

wellon VP-890 Reply  
handsome
aiman said
Hi
Please Add the Arabic language to the program interface
Last post : Re:wellon VP-890 Reply: lxl
do you can help us to Translate from English to Arabic?
All replies (2) [ Posted:2015-02-19 02:52:09 ] Edit Administer TOP"

ISP Problem Reply  
handsome
Babak Aliyari
Hi I have a VP 890 programmer and i want to use my isp cable for programming a jtag port to program a chip but i cannot figure out that what cable is connected to what pin of jtag port please help me if its possible give me the similar name of the jtag
on my isp cable white is XTAL orange is blank (nothing written) red is VCC
yellow is DATA blue is VPP green is blank (nothing written) brown is blank (nothing written) purple is blank (nothing written) gray is CLK black is GND
please help me
Last post : Re:ISP Problem Reply: Babak Aliyari
The chip is NXP LPC2146FBD64
but wellon program does not support this chip in isp mode
can i use another program and if i can whats the name of it
please help
All replies (2) [ Posted:2015-02-16 21:30:50 ] Edit Administer TOP"

wellon VP-890 Reply  
handsome
aiman said
please add language Arabic
Reply the message [ Posted:2015-02-18 23:44:21 ] Edit Administer TOP"

Add S9S12HY64VLL Reply  
handsome
dippy
plz Add S9S12HY64VLL
PROGRAMMER VP990
Last post : Re:Add S9S12HY64VLL Reply: lxl
please download new software
All replies (11) [ Posted:2015-02-04 20:08:29 ] Edit Administer TOP"

NEC UPD 446C and TC 5565apl memory Reply  
handsome
cvbnm
I have VP480 and I am interested how to read and write NEC UPD 446C CMOS RAM and Toshiba TC 5565apl memory?
Thank you for your prompt reply.
Last post : Re:NEC UPD 446C and TC 5565apl memory Reply: lxl
sorry, VP-480 don"t support it.
All replies (3) [ Posted:2015-02-10 17:47:37 ] Edit Administer TOP"

VP990 not working in Windows 8.1 Reply  
handsome
benaknoun
Hello
I have VP990 and Windows 8.1 64bit, i have downloaded latest software and it"s not working, programmer initialization failed, only works in demo mode.
Can you fix this please?
Last post : Re:VP990 not working in Windows 8.1 Reply: benaknoun
Hi
Now it seems to be working, i installed drivers from Weilei folder in Windows...
All replies (1) [ Posted:2015-02-12 06:09:35 ] Edit Administer TOP"

VP-890 and 29F2G08ABAEA Reply  
handsome
ciariello
Hi Sir,
can you add this nand flash to VP-890 SW ?
thanks
Last post : Re:VP-890 and 29F2G08ABAEA Reply: lxl
please download new software.
All replies (1) [ Posted:2015-02-10 03:13:15 ] Edit Administer TOP"

VP-280 Reply  
handsome
abubakar ibrahim
Hi am sadik from Bauchi, Nigeria, i have wellon VP-280 and is doing well....thanks to weilei tech, you guys are doing a great job http://www.weilei.com/lyb/images/p6.gif
Reply the message [ Posted:2015-02-09 18:30:27 ] Edit Administer TOP"

29f200 psop44 Reply  
handsome
phaton
my wellon not read 29f200 psop44 .. why??
Last post : Re:29f200 psop44 Reply: lxl
VP-390 don"t support psop44 package chip,beause hardware.
All replies (3) [ Posted:2015-02-07 18:01:33 ] Edit Administer TOP"

VP990 Windows 8.1 64bit Reply  
handsome
benaknoun
Hi
I have the programmer VP990.
Is it compatible with Windows 8.1 64 bit ?
I need to know because i am changing my computer

Thanks
Last post : Re:VP990 Windows 8.1 64bit Reply: benaknoun
Hi
Do you mean yes it works with Windows 8 64bit?

All replies (2) [ Posted:2015-02-04 20:17:43 ] Edit Administer TOP"

GP-400 accidental FORMAT Reply  
handsome
Kurtman68
we just purchased GP-400 and programmed some EPROMS. Then I accidentally clicked on "FORMAT" button in the Wellon Windows utility software. The progress bar started to move. Then I clicked cancel (or maybe escape, or maybe close window). Now I cannot establish communication between GP400 and my host PC.
Please explain how to fix this.
Thank you.
Last post : Re:GP-400 accidental FORMAT Reply: lxl
please send error photo to weilong@weilei.com.cn
All replies (1) [ Posted:2015-02-06 06:47:31 ] Edit Administer TOP"

windows 8 software for VP280 model Reply  
handsome
cdee
Im using VP-280 model. how to get the software for windows 8. my existing laptop was stolen. anybody please me. Thanks You
Last post : Re:windows 8 software for VP280 model Reply: lxl
sorry,VP-280 don"t support windows8
All replies (1) [ Posted:2015-02-05 18:56:54 ] Edit Administer TOP"

ST 95160 does not correct reading Reply  
handsome
dippy
Hello my dear admin
i use programmer VP-990 new update ver 4.6.5 firmware ver 18.0 , read eprom manufacturer ST 95160 but reading Wrong
Wrong size 2.01KB i some time tray but not good reading , good reading is
size 2.00KB
what problem plz tell me
Last post : Re:ST 95160 does not correct reading Reply: lxl
"File"-->"Save Buffer"-->"Save Buffer to A File"-->"Buffer Size(HEX)"
change from 810 to 800
All replies (3) [ Posted:2015-02-04 23:11:06 ] Edit Administer TOP"

MX 27c4100 with Vp 890 Reply  
handsome
marco
I tried to program this eprom from Macronix MX 27c4100 with my vp 890 but the software ssys "The Device isn"t supported"

solution?
Last post : Re:MX 27c4100 with Vp 890 Reply: lxl
"Macronix"

All replies (6) [ Posted:2015-02-02 08:54:34 ] Edit Administer TOP"

mx25l1655dxci Reply  
handsome
separator
please add layout MX25L1655DXCI BGA24 ..
programmer VP990
Last post : Re:mx25l1655dxci Reply: separator
yes update bigthx. very good.. :D
All replies (6) [ Posted:2015-02-01 01:01:20 ] Edit Administer TOP"

Samsung K9F4G08U0B Reply  
handsome
lelobq
Please My VP- 990 does not correct reading of the Samsung K9F4G08U0B have any option to change ?
Last post : Re:Samsung K9F4G08U0B Reply: lelobq
I solved the problem with updating the firmware, had 18.0 and 21.0 and now spent to solve the problem
All replies (2) [ Posted:2015-02-04 06:21:37 ] Edit Administer TOP"

VP-490 Reply  
handsome
Konstantin
Hi,

problem with wellon VP490. Windows7, driver on system is ok - usb devices "Wellon usb programmer". If i connect gren led and blue led lihgting. Double click on wellon icon - programm running, but say "Programmer initiate failure! - The system is in demo mode!" If i disconnect programmer and run programm without, i can select manually programmer and programm allow me make update. During update, leds is blinking. Programm shows "update ok" but no change on programmer work.
Last post : Re:VP-490 Reply: lxl
please download and install new software,
run c:\weilei\wellon\wellon_reset.exe

All replies (3) [ Posted:2015-02-02 19:07:08 ] Edit Administer TOP"

Program Eprom 27c160/27c322 with Vp 890 Reply  
handsome
Maverick
Hello,

I bought a Vp 890,

Now i want to program some 16 bit eeproms St 27c322 and st 27c160

Do I need an adapter?

which one?

Thanks
Maverick
Last post : Re: 27c160/27c322 with Vp 890 Reply: lxl
if DIP package, don"t need
if SOP package, need adapter WL-SOP44-U001

All replies (1) [ Posted:2015-02-01 07:25:03 ] Edit Administer TOP"

windows 7 for vp480 Reply  
handsome
mparedes
I have a vp480, how can I get it to run on a 64bit windows 7 system?
Last post : Re:windows 7 for vp480 Reply: lxx
Sorry, VP-480 can"t run on win7.
All replies (1) [ Posted:2015-01-27 02:20:20 ] Edit Administer TOP"

SOP44 support for VP-390 Reply  
handsome
mamejay
Hello there. I am wishing to program 29L3211 SOP44 chips. I see you have SOP44 adapters on your website.
Which one should I buy and can you add support for this chip to the VP-390?

Thanks
Last post : Re:SOP44 support for VP-390 Reply: lxl
VP596/996/GP400/600/800

All replies (3) [ Posted:2014-02-16 13:48:57 ] Edit Administer TOP"

Newbie - VP-190 - copy NM27C32BQ - Reply  
handsome
ViereckigeAugen
Hello -

I am a newbie and I need help please:
Bought a VP-190 programmer and want to "copy" a NS NM27C32BQ Eprom.
Select done (NMC27C32B - without "Q").
Original Eprom inserted - read (under 1 second) - saved as .bin.
New Eprom inserted - Prog - Warning! Device Code Error - Man.Code:FF Dev. Code:FF

Any idea???
Last post : Re:Newbie - VP-190 - copy NM27C32BQ - Reply: lxl
NMC27C32BQ = NMC27C32B
maybe your chip is bad.

All replies (8) [ Posted:2014-12-12 04:21:48 ] Edit Administer TOP"

SPANSION  S29GL256PxxFFCR1 @64EBGA SPA Reply  
handsome
chotky

PROGRAMMER : VP890
Hello i have 2 bga64
SPANSION  S29GL256PxxFFCR1 @64EBGA

SPANSION  S29GL032NxxFFIR2 @64FBGA

i buy a expensive socket from u WL-EBGA64 - E138 from you but i try and try to read and write this 2 bga flash but cant dump or program , when put socket on zif is detected but reading writing operation = FFFFFFFFFFFFFFFFFFFFFFFFFFFFF

  WHATS WRONG ? i buy a expensive socket :(

im using last software from support

[ The message is modified by chotky ]
[ The message is modified by chotky ]
Last post : Re: S29GL256PxxFFCR1 @64EBGA SPA Reply: lxl
please send error photo to weilong@weilei.com.cn
All replies (1) [ Posted:2015-01-22 22:23:30 ] Edit Administer TOP"

intel da28f320j5 Reply  
handsome
cerrajeriamty
after download the new software cannot read and write da28f320j5 please help me or check this bug i have many problems with intel flash
Last post : Re:intel da28f320j5 Reply: lxl
programmer type?
is adapter correct?
please send error photo to weilong@weilei.com.cn
All replies (1) [ Posted:2015-01-21 14:15:20 ] Edit Administer TOP"

Help with Am28F010 Plc32 Reply  
handsome
kyo
Hello! Please help me with AM28F010 PLC32 in Vp390/Vp596/Vp996 show program fail. With adapter power, set Slow Program/Read. Use The last software version. Best regards.
[ The message is modified by kyo ]
Last post : Re:Help with Am28F010 Plc32 Reply: lxl
maybe your chip is bad.
All replies (3) [ Posted:2015-01-19 20:18:22 ] Edit Administer TOP"

Why adapter are secret? Reply  
handsome
stylius
Hello. I need some info. I want buy vp-996. I want have good programmer, 90 percent chip are eeprop,but sometimes need read flash tsop56. So this adapter will use one time in year. Why adapter schematic are secret? If it not will be secret i can conect tsop56 chip direct with wire and dont need to buy expensive adapter. What can you say about it?
Last post : Re:Why adapter are secret? Reply: lxl
there are IC on our adapter.
All replies (3) [ Posted:2015-01-17 04:05:20 ] Edit Administer TOP"

software fail Reply  
handsome
cerrajeriamty
i can"t download the new software the server is very bad very slow and   before finish the download fail and i can"t use th gp400 when i select   memory the software close alone
Last post : Re:software fail Reply: lxl
please download from www.weilei.com or www.weilei.com.cn
All replies (1) [ Posted:2015-01-16 15:18:24 ] Edit Administer TOP"

HY27US08281A Reply  
handsome
sinfan
I have a problem with HY27US08281A. With VP-990 version from 12.12.2012 noproblem-chip write OK and chip works on his place. With new versions show program OK, but no ok (chip don"t works on his place). After write dump with new version i read it and save. There are 16 byte differences which areon the last line. On the old version buffer size is 1080000, on the new is1080010, but i don"t think that is problem. I don"t understand where is problem
Last post : Re:HY27US08281A Reply: sinfan
Thank you, work!
All replies (2) [ Posted:2015-01-09 01:35:50 ] Edit Administer TOP"

Spansion S29GL128N Reply  
handsome
naji
Which Programmer Models support Spansion S29GL128N (TSOP56)
thanks
Last post : Re:Spansion S29GL128N Reply: lxx
VP-996/VP-596/GP800/GP600/GP400/GP200
All replies (1) [ Posted:2015-01-06 23:31:56 ] Edit Administer TOP"

VP-996 can`t read AM29LV017D Reply  
handsome
PanPancerny
Hi!

I have problem with reading AM29LV017D memories. When I place memory in adapter and start reading, programmer indicates problem with memory connections (few pins blink): http://www.wrkom.pl/am29lv017d.jpg I was trying to clean pins of memory but it doesn`t matter, all connections are good. My memory is in standard TSOP40 package and I am using pin to pin TSOP adapter. Ofcourse adapter works fine with other types of memories, problem is only with AM29LV017D. Can you help me?
Last post : Re:VP-996 can`t read AM29LV017D Reply: lxl
please send your adapter and chip photo to weilong@weilei.com.cn

All replies (7) [ Posted:2015-01-01 22:38:52 ] Edit Administer TOP"

cannot read to buffer VP280 Reply  
handsome
vr2yxt
VP-280, software 4.3.4 firmware 12

I try to read a hex file to buffer but the buffer is empty. From user
manual, it should have a dialogue window open but it have not. 選中檔後,將會彈出一個對話方塊(見5.1.1),點擊“確定”完成檔的讀入。
I also try to read 89c52 to buffer, it is the same. At last, I remove the software and reinstall. It is no difference at all.
Have any setting I have missing. Please advice
Last post : Re:cannot read to buffer VP280 Reply: vr2yxt
Problem Solved.
The software cannot load hex file from CD-ROM.

All replies (2) [ Posted:2015-01-02 17:45:50 ] Edit Administer TOP"

error vp 390 29fxx Reply  
handsome
mastaro
last Relise 4.6.5 adattatre 44-48 pin.

always pin 1 does not touch  if I tried different 29fxx I can read but no writing. helpscrivere. aiuto
Last post : Re:error vp 390 29fxx Reply: lxl
VP-390 don"t support 44 pin package 29F200/400/800 !!!

All replies (3) [ Posted:2014-12-31 14:45:29 ] Edit Administer TOP"

SPANSION  S29GL256PxxFFCR1 @64EBGA Reply  
handsome
chotky
>>.Auto Program......
>>.Program......
>>Device Address:00000000H Device Data:0000H Buffer Data:D001H
>>Auto Program fail!
>> 1,08Sec
----------------------------!


i buy the socket to expensive but this error make me crazy :(
Last post : Re:SPANSION  S29GL256PxxFFCR1 @64EBGA Reply: jin
Tell us what programmer? what adapter? And which version of wellon software you used?

All replies (1) [ Posted:2014-12-24 22:10:23 ] Edit Administer TOP"

where I can buy WL-FBGA63-E135-15 Reply  
handsome
unknown15
where I can buy WL-FBGA63-E135-15
Last post : Re:where I can buy WL-FBGA63-E135-15 Reply: lixinlei
please email to weilong@weilei.com.cn
All replies (3) [ Posted:2014-12-22 20:09:04 ] Edit Administer TOP"

vp896 and vp996 are the same? Reply  
handsome
eliran
vp896 and vp996 are the same? Why I can"t find vp896 in your web
Last post : Re:vp896 and vp996 are the same? Reply: unknown15
such as?
All replies (6) [ Posted:2014-07-15 22:15:46 ] Edit Administer TOP"

WINBOND W25Q64FVXXXX Reply  
handsome
chotky
HELLO THERE IS A BIG PROBLEM WITH WINBOND W25Q64FVXXXX IN THE LIST WE CAN NOT FIND THIS PART NUMBER ANYWAY OTHER PART NUMBER CAN BE USED BUT AS U KNOW THERE IS 3 LOCK BIT ON THE SPI FLASH WINBOND W25Q64FVXXXX IN OTHER PROGRAMMER LIKE BEEPROG2 IT HAVE A OPTION TO ERASE LB1 OR LB2 OR LB3 IN VP-990 NO WE CANT CAN U FIX THAT ???
Last post : Re:WINBOND W25Q64FVXXXX Reply: myx1
click button "config",choose as you need. and "prog config" on the rightside when program.
earse contains flash,OTP and status register.
All replies (1) [ Posted:2014-12-18 06:45:41 ] Edit Administer TOP"

which is the best Wellon?? Reply  
handsome
tammama
which is the best Wellon??
Last post : Re:which is the best Wellon?? Reply: lxl
chip type?
All replies (10) [ Posted:2014-12-11 21:09:42 ] Edit Administer TOP"

PROBLEM WITH VP996 AND JS28F640 Reply  
handsome
wcetina
Hi, I have the VP-996 but I have a problem with memory JS28F640J3D, I have the adapter WL-TSOP56-F640, but the programmer response with "\>>Do not find Adapter! Set Adapter: Run <Read> without chip on the adapter!", I need support, I have the version 4.6.5, thanks
Last post : Re:PROBLEM WITH VP996 AND JS28F640 Reply: lxl
is your adapter correct?
All replies (1) [ Posted:2014-12-16 00:59:32 ] Edit Administer TOP"

hd64f36079lfzv reading but the writing Reply  
handsome
freddycosty
hello I ordered from you a developer wellon-vp996 and an adapter for wl-tqfp64-e030 processor hd64f36079lfzv and not going to the reading but the writing does not work nor please help me thank you.
[ The message is modified by freddycosty ]
Last post : Re: reading but the writing Reply: lxl
please send error photo to weilong@weilei.com.cn
All replies (1) [ Posted:2014-12-14 23:14:17 ] Edit Administer TOP"

problem ID Programmer VP990 Reply  
handsome
john
I made a software change in the software update system programmer and I have problems using the programmer still show all the time after a demonstration of the reading of such information please told me how to fix reset the system programmer?

http://www.iv.pl/images/60450393169259772086.jpg
software 10-12.2014 update
Last post : Re:problem ID Programmer VP990 Reply: lxl
1. download new software.
2. Run software,
3. exit wellon software.
4. run \\weilei\wellon\wellon_reset.exe.
5. if "system updated OK!",your programmer reset.

All replies (1) [ Posted:2014-12-11 23:48:58 ] Edit Administer TOP"

NAND flash Reply  
handsome
Faraday
Do you have manual how to handle NAND flashes with vp-990?
Last post : Re:NAND flash Reply: myx1
4.if not "0x0" choose the same as "2".
5.if second chip has bad blocks.only choose "hard copy(no)verify".this may do not work on the board because of lose value datas on bad block. if do not work,just change another chip.
All replies (2) [ Posted:2014-12-07 18:22:37 ] Edit Administer TOP"

device program maybe fail! VP-390 Reply  
handsome
Max
i have a problem with my programmer VP-390;
programmer initializing failure, possible causes :
1-there are device on the socket.
2-the programmer"s some function is disable !
warning ! device program maybe fail!

what can i do !!!??, please help
Last post : Re:device program maybe fail! VP-390 Reply: lxl
your programmer need repair

All replies (7) [ Posted:2014-10-26 04:46:16 ] Edit Administer TOP"

Samsung K9F6408UOA and Toshiba TC58V64F Reply  
handsome
Mike Brown
I have a Wellon Vp-496 and I"m trying to read the following ICs
Samsung K9F6408UOA
Fujitsu MBM30LV0064
Toshiba TC58V64FT
Toshiba TC58V64AFT

I have Software Version 4.6.4 and I can"t find any of these ICs in the list. What Can I do to programm them. The seller told me that they were supported by VP-496.

Should I do a Firmware update in the programmer itself?

Thanks for help.

[ The message is modified by Mike Brown ]
Last post : Re:Samsung K9F6408UOA Reply: lxl
vp496 support them
All replies (1) [ Posted:2014-12-04 20:11:00 ] Edit Administer TOP"

VP 190 programmer Reply  
handsome
BG
I bought this programmer recently but when i installed the driver software it was not listed there. How do i connect and run it please
Last post : Re:VP 190 programmer Reply: lxl
please see "help"-->"3.3 Installing the USB driver"
All replies (1) [ Posted:2014-11-28 19:58:35 ] Edit Administer TOP"

vp-896 problem starting any operation Reply  
handsome
margwiz
please help to make any opeacion displays the following
message

PROGRAMMER TROUBLE!ID 4248CBD800000036
waited COMMENT
Last post : Re:vp-896 problem starting any operation Reply: lxl
1. download and install newest wellon software.
2. connect wellon programmer and run wellon software.
3. exit wellon software.
4. run c:\weilei\wellon\wellon_reset.exe.
5.if display "system update OK",your programmer reset OK!

All replies (1) [ Posted:2014-11-29 23:15:01 ] Edit Administer TOP"

Nand Remaping Reply  
handsome
markoco
Does anyone know of a good program to identify bad blocks and remap
a 1 gig nand image
there does not seem to be any support here from wellon
[ The message is modified by markoco ]
Last post : Re:Nand Remaping Reply: lxl
wellon software will erase all block,
when program,if any block program fail,this block is marked bad block.
All replies (16) [ Posted:2014-11-17 11:05:43 ] Edit Administer TOP"

can you add bga mx25l1655dxci 10g Reply  
handsome
bloto21
If you could add support for that part :) will be nice.

MX mx25l1655dxci 10g 
BGA
Last post : Re:can you add bga mx25l1655dxci 10g Reply: lxl
please send its datasheet to weilong@weilei.com.cn

All replies (3) [ Posted:2014-11-19 03:03:34 ] Edit Administer TOP"

Support in VP-298 for Winbond W25Q64FV Reply  
handsome
Josephmcd
Recently bought the VP-298 programmer and found that it does not support the Winbond 25Q64FV series SPI flash as listed in the supported devices section of the website. I see the 32Mbit versions are listed in the program, but no 64Mbit versions or higher are listed as selectable devices.

I am running 4.6.5 version of the software, have also tried 4.6.2, but no support there either. Let me know what I need to do to program this device.
Last post : Re:Support for Winbond W25Q64FV Reply: lxl
please download new software later

All replies (4) [ Posted:2014-11-14 05:22:56 ] Edit Administer TOP"