ST7FL39F2MC Reply  
handsome
dippy
pls add ST7FL39F2MC MY VP990 ISP PROGRAMMING
Last post : Re:ST7FL39F2MC Reply: dippy
thanks admin
All replies (11) [ Posted:2015-05-11 22:45:49 ] Edit Administer TOP"

vp-996 Reply  
handsome
Felipe
How to make copy with VP996 nand flash k9gag08u0e please some tricks
Last post : Re:vp-996 Reply: Felipe
I found a working chip and try to READ in 0XFF HARD COPY VERIFY USED PAGE 8628 always comunication error, only read in 0XFF HARD COPY NOT USED but not program. an memory erased and chec blank ok.
All replies (6) [ Posted:2015-05-22 13:31:11 ] Edit Administer TOP"

The VP-996 support the ic MX23L12811 ??? Reply  
handsome
miguel
Hi, the Programmer VP-996 support the ic MX23L12811 ????
Last post : Re:The VP-996 support Reply: lxl
please download new software later
All replies (4) [ Posted:2015-05-06 04:19:10 ] Edit Administer TOP"

MC68HC11PA8 Reply  
handsome
lelobq
Hello, may include MC68HC11PA8 my programmer VP990, thank you.
Last post : Re:MC68HC11PA8 Reply: gxj
Sorry, this chip stop production for some years.So we can not support this chip.
All replies (1) [ Posted:2015-05-21 21:41:01 ] Edit Administer TOP"

info Reply  
handsome
fmfruki4
prejudice and can not buy the product type programmers and adapters directly from you
Reply the message [ Posted:2015-05-15 22:48:47 ] Edit Administer TOP"

vp-990 ADD atmega8-16AU Reply  
handsome
lelobq
hello, can add ATMEGA8-16AU chip, my device is VP-990, thanks
Last post : Re:vp-990 ADD atmega8-16AU Reply: lelobq
thanks
All replies (2) [ Posted:2015-05-15 03:26:06 ] Edit Administer TOP"

info Reply  
handsome
fmfruki4
salve non e possibile acquistare i prodotti tipo programmatori e adattatori direttamente da voi
Last post : Re:info Reply: lxl
please use English
All replies (1) [ Posted:2015-05-15 11:42:52 ] Edit Administer TOP"

29f400 44pin Reply  
handsome
fmfruki4
ciao a tutti ho un lettore vp390 ho la necessita di leggere una am29f400 44pin ma il software mi richiede una am29f400 48pin non c"è nessuna speranza di leggerla con questo programmatore anche acquistando un adattatore
Last post : Re:29f400 44pin Reply: lxl
sorry, VP390 don"t support 44 pin package of 29f400
All replies (1) [ Posted:2015-05-14 12:48:53 ] Edit Administer TOP"

VP-390 / PROBLEM AFTER UPDATE / 29Fx00 Reply  
handsome
Seiz
Hello,

I"ve buy wellon VP-390 to remplace Willem GQ-3X and work on chip 29Fx00.

I"ve problem because he doesn"t work to read this chip. I"ve adapter for this chip.

I can"t make check blank, write or other.

I try update sofware but now I"ve an error and nothing work.

Before I could see the pin check but now, nothing.


Please, have you an idea for me or another methode to update the firmware programmer ?

Thank you

[ The message is modified by Seiz ]
Last post : Re:VP-390 / 29Fx00 Reply: lxl
please send error photo to weilong@weilei.com.cn
All replies (1) [ Posted:2015-05-11 18:08:12 ] Edit Administer TOP"

i use vp 990 plz add ST7FL39F2MC Reply  
handsome
dippy
HELLO MY DEAR I USE VP990 I NEED ST7FL39F2MC PLS ADD THIS MC ISP PROGRAMMING
Reply the message [ Posted:2015-05-09 22:44:07 ] Edit Administer TOP"

vp-38a Reply  
handsome
birgirl
hello ~~

i have vp-38a ...It has two.
and
i have vp-390 it has one..

but~

my programmer ... vp-38a

old model ..

this programmer trouble...

send me.. reset file.....

Please send to my email -

[ The message is modified by birgirl ]
Last post : Re:vp-38a Reply: lxl
VP-38A have stop produce eight years,cannot to initialize. maybe its hardware is bad.
All replies (6) [ Posted:2015-05-08 15:25:39 ] Edit Administer TOP"

Spansion S99-50243D TSOP48 Reply  
handsome
lelobq
Hello , may include Spansion S99-50243D TSOP48 VP- 990 .
Last post : Re:Spansion S99-50243D TSOP48 Reply: lxl
Please download new wellon software
All replies (5) [ Posted:2015-04-21 03:28:01 ] Edit Administer TOP"

gp2 trouble id Reply  
handsome
salemdecod20
hello
need help gp2 programmer write troube programmer id,
cant read devise
Last post : Re:gp2 trouble id Reply: lxl
have sent you reset file.
All replies (1) [ Posted:2015-05-03 16:49:50 ] Edit Administer TOP"

vp 390 Reply  
handsome
retiredxxx
purchased a vp-390 recently and it was working fine. im only flashing
M27C322 and M27c160 . they have been flashing fine but recently i noticed the program was crashin so resintalled and now gives error trouble ID:
39AB6B2301000003B..i tryed well_reset.exe and i get error after error. i dont get whats going on :( tryed installing 64but older version. everything. still not working again. been a few days and still cant get it up. tryed another pc as well.same issue.
Last post : Re:vp 390 Reply: lxl
please send reset error photo to weilong@weilei.com.cn
All replies (1) [ Posted:2015-05-02 06:00:27 ] Edit Administer TOP"

stm8s105k4t6c Reply  
handsome
lelobq
you can include stm8s105k4t6c 32 pins
Last post : Re:stm8s105k4t6c Reply: lxk
VP996/596 support it.
All replies (1) [ Posted:2015-04-29 18:37:52 ] Edit Administer TOP"

Catalyst 93C66 Reply  
handsome
currenttech
Hi,

Using your VP-390 I"m currently trying to program a Catalyst 93C66SI 0742E chip. I can read and erase the chip no problem but programming comes up with the following message:

Auto Program.......
Program.........
Device Address:00000007 Device Data:FFFH Buffer Data:16FAH
Auto Program Fail

Thanks in advance.
Last post : Re:Catalyst 93C66 Reply: lxl
please try to change "Setting"-->"Modify .."-->"tPW" from "10" to "20"

All replies (1) [ Posted:2015-04-25 15:54:39 ] Edit Administer TOP"

VP-490 and MX23C3210PC Reply  
handsome
hemvlett
Hello,
Could you tell me if it"s possible to program Macronix MX23C3210PC with a VP-490?

Thanks.

Julien F
Last post : Re:VP-490 and MX23C3210PC Reply: lxl
MX23C3210 do not need program

All replies (1) [ Posted:2015-04-24 06:04:40 ] Edit Administer TOP"

WL-EBGA64-E138/E248 Adapter modify! Reply  
handsome
RTVM
Hi,

i have WL-EBGA64-E138 adapter and i need to programm Spansion GL512N11FFA02 flash chip.
Can you tell me how to set proper jumpers on the adapter for use as
WL-EBGA64-E248 ?
Take a look at this pictures:

https://www.dropbox.com/sh/029i3jzjylxvqqa/AABa4ZUVm7TRPkC2cZgTGi6Qa?dl=0

Thanks,

RTVM

[ The message is modified by RTVM ]
Last post : Re:WL-EBGA64-E138/E248 Adapter modify! Reply: RTVM
Can you sell me it direct? Price?

Thanks,

RTVM

All replies (8) [ Posted:2015-04-22 16:31:40 ] Edit Administer TOP"

Lattice isplsi 2032A Reply  
handsome
kribech.a
I want to program a Lattice ISPLSI 2032A With a WELLON VP-390 Programmer , please your help
Last post : Re:Lattice isplsi 2032A Reply: lxl
sorry, VP-390 do not support it.
All replies (1) [ Posted:2015-04-22 17:20:29 ] Edit Administer TOP"

stm8s Reply  
handsome
lelobq
hello, can include stm8s005k6t6c, stm8s105s4t6c, (ISP) thank you
Last post : Re:stm8s Reply: lxl
please download new software
All replies (3) [ Posted:2015-04-10 18:05:32 ] Edit Administer TOP"

at88sc0808cs Reply  
handsome
wee
can we clone atmel at88sc0808ca if we have the password 7 code? if can ,how do we clone the chip with your wellon programmer vp996?
Last post : Re:at88sc0808cs Reply: gxj
the config include password area, so you can use correct password 
to read chip
All replies (1) [ Posted:2015-04-18 23:04:15 ] Edit Administer TOP"

μPD78F0034A Reply  
handsome
lelobq
hello , can include μPD78F0034A VP990
Last post : Re:μPD78F0034A Reply: lxl
please use V4.6.5 software.
All replies (1) [ Posted:2015-04-17 20:13:55 ] Edit Administer TOP"

VP490 changed to VP190 Reply  
handsome
franky28
Hello,
After installing 4.6.5 my VP-490 (SN 4906-2290) changed to VP-190 (SN 1906-1290). The Software goes into demo mode and shows the error "The programmer type error!please notice Manufacture!".
The wellon-reset.exe didn"t help. Now it also doesn"t work under 4.6.4.
What can I do?
Last post : Re:VP490 changed to VP190 Reply: lxx
Please use the newest software 4.6.5.
All replies (1) [ Posted:2015-04-18 03:29:51 ] Edit Administer TOP"

Programmer trouble!ID: 41F8BFF200000028 Reply  
handsome
cidak
Hello, I have a problem with the VP-996.

After installing the latest software version 4.6.5 02/04/2015 programmer has updated the FW22.0, up to here all right, but if you make any operation, the answer is "Programmer trouble! ID: 41F8BFF200000028" .

The only thing working is the test of integrated circuits TTL, and their recognition.

Last post : Programmer trouble!ID: 41F8BFF200000028 Reply: cidak
Tanks LXL.
Resolved.

All replies (4) [ Posted:2015-04-06 16:55:24 ] Edit Administer TOP"

I JUST PURCHASE THE VP-896 Reply  
handsome
ecking767
purchase a VP896, Download the latest software 4.6.5,the unit firmware version is 21.0. running Windows 7 pro 32bit.I am trying to read and write to a HYNX H27UAG8T2B.After reading the H27UAG8T2B I have a checksum,when I save the buffer to a file the checksum reads 0000
Last post : Re:I JUST PURCHASE THE VP-896 Reply: myx1
if there are not bad blocks,it is perfect.
but if it has bad, you"d better use "hard(no verify)" to flash.wish the bad do not contain the valid datas(like boot).
if this,maybe work. if not,it fails.try another chip.
All replies (41) [ Posted:2015-01-10 19:02:44 ] Edit Administer TOP"

AT27c4096 Reply  
handsome
lotharek
Hello Guys,

simple question :

try to read on VP990 following plcc chips:

-at27c4096
-HN27c4096

both new - but adapter fails at insertion test - adapter is brand new WL-plc44-u1 -- the same pins all the time - at plcc 26,32,37

On other adapter - 1:1 plc44-DIP - the same situation

after CONTINUE on insertion test pop-up window - vp990 reads and fills up buffer


Please, advice
Last post : Re:AT27c4096 Reply: lxx
Please give your programmer a self-test. If it don"t have any wrong,it means that your chip"pin is oxidation, dirty or damage.

All replies (1) [ Posted:2015-04-10 02:47:02 ] Edit Administer TOP"

VP-996 Programmer to program ALTERA IC Reply  
handsome
mugu1402
I"m planing to purchase the VP-996 Wellon Programmer, but coccould you confirm whether it can copy and program IC ALTERA EPM3064ATC44?
Last post : Re:VP-996 to program ALTERA IC Reply: lxl
support svf file program.
All replies (1) [ Posted:2015-04-06 10:24:31 ] Edit Administer TOP"

MY VP590 Reply  
handsome
PLACANEW
Hi,

IN MY VP 590 IS POSSIBLE READ TMP47C IN PROM MODE?
IF POSSIBLE GIVE ME THE WAY IN PROGRAMMER.

TKS
ROGER

Sorry...TMP47C443NG or TMP47P443NG

[ The message is modified by PLACANEW ]
[ The message is modified by PLACANEW ]
Last post : Re:MY VP590 Reply: PLACANEW
Tks for your attention.
All replies (4) [ Posted:2015-04-03 18:59:44 ] Edit Administer TOP"

A29L008ATV Problem Reply  
handsome
eugen
Use VP896 with last Software
A29L008ATV-70F program not correct
If I fill the buffer with 00H, 0FH or F0H it program
But it not works with 66H, 69H or 96H in the buffer
Similar failures:
Device Address: 00000002H Device Data:89H Buffer Data:69H
I tested ICs from various sources
With slow Program, with various tPW and Retry
Adapter (WL-TSOP48-U001) is clean and works with other chips
It may be works with other chips like AM29LV008 (not tested). But not with this IC
Last post : Re:A29L008ATV Problem Reply: lxl
please download new software
All replies (5) [ Posted:2015-03-17 19:49:14 ] Edit Administer TOP"

VP390 config option Reply  
handsome
alex38
Hello
i have a VP390 and i tryed need to programme a PIC12F629,i loaded the hex file and setted the config option,but unfortunaltly the config option are not programmed in the pic,
i selected prog config ,i tryed manually or in auto mode but just the hex file seems loaded in the pic,no the config options.
Last post : Re:VP390 config option Reply: weilei.com
Hello,
Please set the config and selected prog config! If you have some
problem,you could e-mail to us!
All replies (1) [ Posted:2015-03-30 04:09:33 ] Edit Administer TOP"

vp-390.. pic12c508a Reply  
handsome
birgirl
to use the vp-390, when compared to the data after writing pic12c508a chip, the data comes out different from each other. Already abandoned more than 10 chips.
What Is the problem? vp-390 is this bad?
Last post : Re:vp-390.. pic12c508a Reply: birgirl
Give the confirmation email sent to answer.
All replies (2) [ Posted:2015-03-28 14:25:20 ] Edit Administer TOP"

VP-298 Reply  
handsome
ocnek
Hello,

Are there command line tools for the VP-298. I would like to setup some automatic programming.

Thanks.

Reply the message [ Posted:2015-03-27 00:26:26 ] Edit Administer TOP"

Ramtest Reply  
beautiful
Zsolt Bojtos
Is it possible to add, or make new algorithm for the followes :

Type of sram:

MB81C79A-45 , and MB8416A-15

rgds

Zsolt
Last post : Re:Ramtest Reply: zsbojtos
Thanks for your quick help. It"s working perfectly!!

Thanks again!!

Zsolt

All replies (5) [ Posted:2015-03-25 18:53:42 ] Edit Administer TOP"

Add PIC18F458 Reply  
handsome
chaosOne21
Hey, I just bought a VP-390 programmer and I need to program Michrochip"s
PIC 18F458 but it"s not in there.
Can you please include it ASAP ?
Last post : Re:Add PIC18F458 Reply: lxl
sorry, VP390 don"t support it.
All replies (1) [ Posted:2015-03-26 16:21:26 ] Edit Administer TOP"

LPC1113 on VP-990E Reply  
handsome
Thomas
Hi, i was wondering if the VP-990E is able to program an LPC1113 usig ISP?
When I use an FTDI cable i know i have to use an adapter to control the RST signal, otherwise it wont work.

edit: the page with supported models loaded very slowly, i"ve found the entry already but couldn"t find a button to delete my post

[ The message is modified by Thomas ]
Last post : Re:LPC1113 on VP-990E Reply: lxl
VP-990E supports LPC1113 usig ISP.
All replies (1) [ Posted:2015-03-24 18:41:23 ] Edit Administer TOP"

help me~ Reply  
handsome
birgirl
The use of vp-390.
Help came out the words: >>Programmer trouble!ID: 3965D534000000D1
Last post : Re:help me~ Reply: lxl
1. download and install new software.
2. run wellon software and exit wellon software.
3. run c:\weilei\wellon\wellon_reset.exe.
  if display "sys update ok!" ,the programmer reset OK.

All replies (1) [ Posted:2015-03-24 01:43:57 ] Edit Administer TOP"

NEW USER CYBERPUNK Reply  
handsome
cyberpunk
#CYBERPUNK #CAR

Reply the message [ Posted:2015-03-21 10:32:01 ] Edit Administer TOP"

WELLON VP-990 Reply  
handsome
ars44
Hi, my programmer stops working vp-990. It began with the fact that he tried to program with any chip gave an error - programmer trouble! ID: 01D414FFFFFFFFFF. But then it could still read without errors chip. Then he stopped reading them as well. Of instructions read that it is necessary to update the firmware shorting jumper. I did so.
Last post : Re:WELLON VP-990 Reply: ars44
I sent foto to your email.
All replies (6) [ Posted:2015-03-12 21:11:07 ] Edit Administer TOP"

wellon VP-890 Reply  
handsome
aiman said

hi-please add PIC32MX250
Last post : Re:wellon VP-890 Reply: aiman said
Thank you very much!
All replies (3) [ Posted:2015-03-13 07:57:38 ] Edit Administer TOP"

intel flash da28f320j5 Reply  
handsome
cerrajeriamty
after udpdate firmware and software of gp400 now cannnot write intel flash only read erase but not write new file please check this problem software 4.6.5 firmware 21.0

please help me i bought gp400 only to read and program this intel flash and after update firmware have problems 

[ The message is modified by cerrajeriamty ]
Last post : Re:intel flash da28f320j5 Reply: lxl
please send error photo to weilong@weilei.com.cn
All replies (1) [ Posted:2015-03-15 09:09:50 ] Edit Administer TOP"

Fujitsu MB8516 with Vp 890 Reply  
handsome
Marco74
I have to program some Fujitsu MB8516 with Vp 890

is it possible?

I do not see it in the list, if i click on the "Auto ID" it says nothing...

Any solution?

Thanks
Marco
Last post : Re:Fujitsu MB8516 with Vp 890 Reply: lxl
no.

All replies (3) [ Posted:2015-03-13 05:16:39 ] Edit Administer TOP"

STM8S207/208 ST Reply  
handsome
lelobq
Hello , may include MCU STM8S207/208 ST
Last post : Re:STM8S207/208 ST Reply: lxl
please download new software.
All replies (3) [ Posted:2015-03-04 04:04:40 ] Edit Administer TOP"

K9F2G08U08B Reply  
handsome
lelobq
Hello , I have a problem with K9F2G08U08B memory, has not identical copy, it is 256M but only makes copy 132M , there"s something wrong , wait.
Last post : Re:K9F2G08U08B Reply: lxl
please send error photo to weilong@weilei.com.cn
All replies (1) [ Posted:2015-03-04 19:01:53 ] Edit Administer TOP"

at88sc0808ca Reply  
handsome
wee
can i clone a at88sc0808ca eprom even if this chip is encryted with password? i can read the chip but the detail is encryted so i just want to clone this for spare if the original is spoilt.
Last post : Re:at88sc0808ca Reply: lxl
no,you cannot
All replies (1) [ Posted:2015-03-03 20:26:52 ] Edit Administer TOP"

ttl & cmos test with vp-480 Reply  
handsome
kallquk
Hi. I have a big quantity of used 74HC373D. Can I perform the test above to this IC ? with the smallest doubt I have to garbage it !

It is not in the list so I created it with add pattern consulting its datasheet, I resulted:

v1:0L00LL00LG1L00LL00LV
v2:0H11HH11HG1H11HH11HV
v3:0L00LL00LG0L00LL00LV
v4:0H11HH11HG0H11HH11HV

where I thought to leave out 2 tests, because I could not interpret the state "high impedance state off" for output

[ The message is modified by kallquk ]
Last post : Re:ttl & cmos test with vp-480 Reply: lxl
naybe your programmer is bad. this programmer is elder product.
All replies (5) [ Posted:2015-02-23 03:52:31 ] Edit Administer TOP"

Please Help Reply  
handsome
Babak Aliyari
The chip is NXP LPC2146FBD64
but wellon program does not support this chip in isp mode
can i use another program and if i can whats the name of it
please help and one more thing its on my M-Audio mainboard and my axiom pro 49 screen is dead
Last post : Re:Please Help Reply: gxj
we will add it as soon as possible
All replies (1) [ Posted:2015-02-24 20:48:18 ] Edit Administer TOP"

at88sc0808ca Reply  
handsome
wee
I have a vp996 and i cant read the at88sc0808ca thru isp?can you help?
Last post : Re:at88sc0808ca Reply: lxl
at88sc0808ca usually is Encryption
All replies (1) [ Posted:2015-03-01 22:21:16 ] Edit Administer TOP"

EMP-290..I have two questions. Reply  
handsome
markh27
I recently purchased an EMP-290 from Needhams Eletronics and weilei.com is listed on the instruction booklet.

I have two issues:

1 - How do I get it out of "demo mode"

2 - Should it have an ac adapter plug? I use the USB cord and I assume it is getting power because the green G/E light is illuminated.
Last post : Re:EMP-290..I have two questions. Reply: lxl
please reinstall usb driver. it is at c:\weilei\wellon\usbsys

All replies (3) [ Posted:2015-02-27 07:31:48 ] Edit Administer TOP"

6821 Reply  
handsome
Drx
hi,
I have a vp-290, I check a 40pin 6821?
Last post : Re:6821 Reply: lxl
sorry,we have not its datasheet.
All replies (1) [ Posted:2015-02-25 18:18:32 ] Edit Administer TOP"

Sharp LRS1396 Reply  
handsome
sukhorukov
Please add Sharp LRS1396 to the list for VP990. Xeltek supports it: http://www.xeltek.com/device_lists/SHARP/LRS1396/

Thanks.
Last post : Re:Sharp LRS1396 Reply: lxl
sorry,we do not find its datasheet

All replies (3) [ Posted:2013-04-05 01:12:57 ] Edit Administer TOP"